Model | 2B2KL(S) | 2B3KL(S) | 2B3.75 KL(S) | 2B5K/2B6KL(S) | 2B10K | |
Output capacity | 2000VA | 3000VA | 3750VA | 5000/6000VA | 10000VA | |
Input | Voltage | 110VAC±20%/220VAC±25% | ||||
Frequency | 60Hz±5%/50Hz±5% | |||||
Ouput | Voltage | 110V±1%/220V±1% | ||||
Frequency | 60Hz±0.5%/50Hz±0.5%(Free running) | |||||
Distortion | THD<5%;THD<3% Non linear load THD<5%;resistance load thd<3% | |||||
Stability voltage at transient state | Full load±4% | |||||
wave form | Sine wave | |||||
Crest factor | 3:1 | |||||
Power factor | 0.8-1 LAG | |||||
AC/AC | >85% | |||||
Battery | DC Voltage | 96V | 192V | |||
Number | 12V/7Ah×8pCS | 12V/7Ah×16pCS | ||||
Transfer time | AC fault | 0ms | ||||
UPS fault | <2ms | |||||
Alarm | AC fault | alarm every 4 seconds?stop after90 seconds | ||||
battery low voltage | alarm every 1 seconds until cut-off and battery LED flash every 2 seconds | |||||
UPS over load | Continue voice | |||||
UPS fault | Continue voice | |||||
Protection | Over load | 125%load ,change to by-pass and auto-restart after 25s | ||||
Battery | Circuit breaker | |||||
Short circuit | Breaker, current limited and cut-off | |||||
Over temperature | >85?change to by-pass | |||||
EMI filter | 150~500K Hz ,79dB /500K~30M Hz ,73dB | |||||
Display | LED | mains input/by pass/inverter/battery/over load/fault | ||||
LCD | Input &,output voltage or battery voltage/frequency/load rate/UPS condition/temperature | |||||
Interface | RS232 | mains/inverter voltage/battery capacity/load capacity/mains frequency/temperature/ time-shutdown etc | ||||
General data | Temperature | 0?~40? | ||||
Humidity | 20~90% No condensing | |||||
Noise | <58dB at 1 meter | |||||
Noise(at 1 meter) | 56/85kg | 64/93kg | 64/93kg | 77/126 kg | 106 kg | |
Dimension | 585*230*720mm | 585*230*580mm | 585*230*720mm | 585*230*580mm | 480×340×845mm | |
Output socket | 1 connection bus |